In order to create or adjust the buzzer or bell schedule directly from the clock, follow these steps:
- Access the clock by using a card or PIN of a clock supervisor level account
- On the Supervisor menu, select Exit App to restart the device
- As the device restarts and the Synerion logo is displayed with a progress bar, click on the gear icon at the bottom right of the screen
- When prompted, enter the supervisor PIN
- In the Terminal Setup menu, select Application
- In the Application menu, select Setup (Synerion Agile)
- Select Relay Schedules
- In the Configure relay schedules menu, select Configure relay times
- The number of existing relay schedules is shown in brackets to the right
- Select Add relay time
- On the Enter relay on time menu, set the time to the time the buzzer or bell should start ringing (example: 7:00:00am)
- Times should be set using 24h time (7:00:00pm = 19:00:00)
- Click Next
- On the Enter relay off time menu, set the time to the time the buzzer or bell should stop ringing (example: 7:00:05am if the buzzer or bell should ring for five (5) seconds.) Adjust the ‘Off Time’ as needed based on your requirements
- Times should be set using 24h time (7:00:00pm = 19:00:00)
- Click Next
- On the Select the day(s) of week menu, select the days of the week this schedule should apply to using the buttons to the right of the days of the week.
- Click Next
- On the Select the relay to control menu, select the IO board and relay that is connected to the clock (typically IO board 1 relay 1)
- Click Next
- Create the rest of the schedule by repeating steps 9 through 17
Relay Times can not be modified – if a change is required, the schedule needs to be deleted and recreated with the proper configuration.
Relay Time schedules can be deleted by selecting the relay schedule from the menu, and clicking Delete.